RV 80 BOARD with MONITOR - 40amp, DC/DC, Solar and 240volt.
Key features:
- Reliable Performance: The ePOWER Low Battery Cutoff safeguards batteries from non-essential discharges, ensuring engine starting power and protecting connected appliances from overvoltage.
- Microprocessor Control: Features 10 programs to manage voltage load engagement or disengagement across various voltage parameters.
- Safety Features: Includes overvoltage protection, ignition proof design (no relay, no spark), delayed alarm output, and delayed load disconnect.
- Versatile Applications: Suitable for recreational vehicles, service vehicles, and marine equipment.
- Easy Installation: Designed for easy assembly with provided wiring and mounting instructions.
High Output: Provides 40A to 50A output with a 775W power rating, selectable battery types (Gel, AGM, Flooded, Lithium, Program).
Charging Control: Features four-stage charging (Bulk/Absorption/Float/Maintenance) and supports a variety of battery types.
Input and Efficiency: Accepts wide input voltage ranges (90 to 265 VAC), power factor correction, and 82% charger efficiency.
Protection and Features: Equipped with reverse polarity, overcharge, over temperature, and output short circuit protection, with forced air ventilation.
Environmental Specs: Operates in temperatures from -20° to 60°C, with IP32 ingress protection and includes an LCD display for monitoring charging status.
Comprehensive Kits: Enerdrive's RV Installation Kits are designed for 4WD canopies, caravans, camper trailers, commercial work vehicles, and more.
Versatile Layouts: Multiple layouts available to fit nearly every application, suitable for DIY handymen and professionals.
Pre-Wired for Simplicity: Kits are pre-wired where possible, with full wiring diagrams included for easy installation.
Durable Construction: Mounted on a 12mm black plastic board that is water and rot-resistant.
Service and Support: Enerdrive offers comprehensive service and support, with detailed knowledge of each kit's layout and wiring.
Ouput Rating | |
Output Voltage | 12V Nominal (8.0V min) |
Output Current (Maximum) | 40A – 50A |
Output power | 775W |
Charger DC Output (CH1): | |
Selectable Battery Type | Gel, AGM, Flooded, Lithium, Program |
Charger Voltage Range | 13.8V – 15.5V |
Float Voltage Range | 13.0V – 13.8V |
Charger Current (User Selectable) | 5/10/15/20/25/30/35/40/45/50A (default 40A) |
Equalize Voltage (flooded Battery) | 15.5V |
Equalize Charging Current | 10% of Bulk Current Setting |
Charging Control | 2 stage / 3 stage selectable (Default 3 stage) |
DC Output Bank | Single |
Current draw from CH1 when in use | = 50mA |
Battery Temperature Setting | Low/ Normal/ High (Battery Temperature Sensor Standard) |
Efficiency | 95% |
Input Rating (CH2 – MPPT Solar) | |
Input Voltage | 14.5 – 45VOC |
Maximum Input | ≤23 input, 500W (600W allowable) ≥37.5-45V input, 750W (800W allowable) |
Input Rating (CH3 – Start/Alternator) | |
Input Voltage | 10.5 – 16VDC / 21 – 32DC |
Dimensions | |
Height x Width x Depth | 242mm x 172mm x 74mm |
Unit Weight | 1.85 Kg |
Shipping Weight | 2.17 Kg |
EN31240-
Model | EN31220 | EN31240 | EN31260 | EN32430 |
CHARGER OUTPUT | ||||
Output Current (Maximum) | 20A | 40A | 60A | 30A |
OUTPUT VOLTAGE RANGE | ||||
Charge | 14.2 – 15.5 V | 28.4 – 31.0V | ||
Float | 13.4 – 13.8 V | 26.8 – 27.6V | ||
– Equalize | 16.0 V | 32.0V | ||
Charging Control | Four stages (Bulk/Absorption/Float/Maintenance) | |||
Two stages (Bulk/Absorption) | ||||
Constant Power Supply (Program setting) | ||||
Priority Battery Bank Charging | ||||
DC Output Bank | Three (1 fully independent, 2 common with diode isolation) | |||
Selectable Battery Type | Gel, AGM, Flooded, Lithium, Program | |||
Standby Current | 2 mA | |||
CHARGER INPUT | ||||
AC Input Voltage (Nominal) | 90 to 265 VAC | |||
AC Input Operating Range | 207-265 Vac (2.0 A Max)90-125 Vac (3.8 A Max) | 207-265 Vac (3.8 A Max)90 – 125 Vac (7.7 A Max) | 207-265 Vac (5.9 A Max)90-125 Vac (11.3 A Max) | 207-265 Vac (5.9 A Max)90-125 Vac (11.3 A Max) |
AC Input Frequency Range | 47 – 63 Hz | |||
Power Consumption | 350W (Full Load) | 700W (Full Load) | 1050W (Full Load) | 1050W (Full Load) |
Power Factor Correction | Yes | |||
Charger Efficiency | 82% | |||
PROTECTION AND FEATURES | ||||
Reverse Polarity | Yes, (with user replaceable fuse/s) | |||
Over Charge | Yes, unit shutdown | |||
Over Temperature | Yes, unit de-rated and shutdown | |||
Output Short Circuit | Yes, (with user replaceable fuse/s) | |||
Cooling | Forced air ventilation (thermo controlled fan) | |||
Temperature Setting | Hot, Normal, Cold (no sensor connected) | |||
Battery Temp Sensor Port | RJ12 (standard battery temp. sensor supplied) | |||
DISPLAY | ||||
LCD Display (with back light) | Charging status, Battery Voltage, Output Current and Fault Codes. | |||
AC INPUT AND DC OUTPUT CONNECTION | ||||
AC Input Connection | IEC with Supplied 1.2M Power Lead | |||
DC Output Connection | Heavy Duty Terminal (3 banks) – Pan Heads 6mm Thread | |||
DC Output Ground | Single Heavy Duty Common Ground Stud | |||
ENVIRONMENTAL AND OPERATING TEMPERATURE | ||||
Storage Range | -40° to 70° C | |||
Operating Range | -20° to 60° C | |||
Humidity | 5-95%, relative humidity non-condensing | |||
Ingress Protection | IP32 (Basic drip proof in vertical orientation) | |||
Base Unit Weight and Dimensions | ||||
Weight: (kg) | 2.4 | 2.6 | 4.0 | 4.0 |
Dimension: (mm) L x W x H | 295 x 206 x 86 | 295 x 206 x 86 | 356 x 206 x 99 | 356 x 206 x 99 |
Optional Accessories | Remote Digital Display / Enerdrive Part Number EN3REM | |||
Regulatory Compliance | Complies with AS/NZS 60335.2.29 Including Australian deviations. |